Add to Cart
Waste Water Treatment Plant Sodium Hypochlorite generator From Dilute Brine Water
Company Introduction
Guangzhou Geemblue Environmental Equipment Co., Ltd. is a high-tech enterprise which devoting energy into the development and application of the most advanced water treatment technology. It holds 4 patents of inventions, 15 utility model patents, Appearance patent and a total of 21 software copyrights, besides that, Geemblue is also undertaking 15 research projects of Guangzhou local Government.
The company has been focusing on serving municipal utility plants, sewage treatment plants, power plants, oil platforms, mariculture and food processing plants, etc. and providing quality water treatment equipment and water treatment solutions, so far, the company has been a business partner of many large environmental companies at home and abroad.
Principle of sodium hypochlorite generator
Salt solution contains the several kinds of ions such as Na +, H -, when electrolysis, under a certain voltage, as a result of the movement of ions in the electrolyte solution and electrode reaction, the conductive effect occurs, then CL -, OH - such as negative ion to the anode, and positive ions such as Na +, H + to the cathode, and the corresponding electrode discharge occurs, thus carries on the REDOX reaction, the corresponding material production. The electrode reaction and solution reactions is
Electrode reaction:
anode: 2Cl- - 2e → Cl2;
cathode: 2H+ + 2e → H2;
Solution reaction:
2NaOH + Cl2 → NaCl + NaClO + H2O
Overall reaction as follow:
Na Cl + H2O + DC →NaClO + H2↑
Product components
Electrolytic cell
Geemblue series unique electrolytic cell design optimizes salt and power consumption while providing easy access to the cell components for maintenance. A clear organic glass cell body allows for visual inspection, and the improved end-connection cap design minimizes the potential for leaks.
Electrode
TA1 pure titanium electrode, with ruthenium &iridium oxide coating which ensure over 5 years coating life, over 18 years base material, reduce the chlorine evolution potential and electricity consumption.
Project Reference
Water flow(MLD) | Capacity | Chlorine concentration(ppm) | Dosing rate(ppm) | Control | Salt consumption | Energy consumption | |
Hunan waste water plant disinfection | 180 | 15kg/h*3 (two duty one standby) | 8000 | 3 | PLC control/full automatic | 3.5 kg/kg Cl2 | 4kwh/kg Cl2 |
Malaysia Water plant disinfection | 20 | 2kg/h*2 (two duty) | 8000 | 4 | PLC control/full automatic | 3.5 kg/kg Cl2 | 4kwh/kg Cl2 |
Indonesia Water plant disinfection | 30 | 6kg/h (one duty) | 8000 | 4 | PLC control/full automatic | 3.5 kg/kg Cl2 | 4kwh/kg Cl2 |
Malaysia Water plant disinfection | 17 | 3kg/h*2 (one duty one standby)
| 8000 | 4 | PLC control/full automatic | 3.5 kg/kg Cl2 | 4kwh/kg Cl2 |