Add to Cart
Magnetic Fenton Package System for Printing Waste water
Advantage
Waste Water Plant Request
The source of wastewater is mainly leather wastewater and chemical wastewater, as well as a small amount of wastewater from electroplating, food and other industries. After the transformation, the effluent water quality shall meets the requirements of Class A discharge standards.
Result
Fluidized bed Fenton transformation. After the transformation, the annual operating cost saved by about 0.4 million USD.
Owner of the waste water plant is Rahill water
Specifications:
Items | Fluidized bed fenton | Geemblue Magnetic fenton | |
Treatment condition | Initial PH | 3~4 | 4-5 |
Chemical consumption | 98% H2SO4 | 350mg/L | 250mg/L |
FeSO4 | 400mg/L | 300mg/L | |
27.5% H2O2 | 450mg/L | 220mg/L | |
30% NaOH | 800mg/L | 600mg/L | |
Filler | Require to use and replace regularly | No filler required, no Stiffening or clogging occur | |
Main Chemical cost | 0.315 USD/ton | 0.195 USD/ton | |
If use Jinchuan special chemical cost | / | 0.175 USD/ton | |
Effect | CODcr | < 50mg/L | < 50mg/L |
Civil construction | Reaction pool | Require degassing | No degassing require |